RoboFill Preventative Maintenance Consists of the Following:

Electrical power cord is rated for 110V /60Hz outlet.Check all accessible screws -tight and to full depth.
Check all electrical and communication connections for secure engagement.
Check all air line connections for secure engagement.
All system components show no obvious sign of damage.
Check that the Teach Pendant cable securely engages in the Teach Pendant and the RF300.
Check the RF300 base plate is securely fastened.
Check that all air fittings are tightened and sealed using Teflon tape.
Check all exposed edges for burrs or sharp edges.
Check that the Valve adjustment screw rotates freely with locking nut loosened.
Check that the Valve adjustment screw does not rotate with locking nut tightened.
Check that the Pressure Vessel stand is securely assembled.
Check that the air inlet assembly is mounted to the stand and securely fastened.
Check that the 8000D control box is mounted to the stand and securely fastened.
Check that the PV stand has (2) vessel mount blocks that are securely fastened.
Check that the vessel mount blocks are spaced 10” apart with pins protruding upwards and that the longer of the two block pins are on the bottom block.
Check that the Pressure vessel securely fits over mounting pins and rest on mount blocks.
Check that the “Pinch Point” sticker is clearly visible on the Robot cross member.
Check that the “Read Manual” sticker is clearly visible on the front of Robot.
Electrical power cord is rated for 110V/60Hz outlet.